Saturday, January 21, 2017

kirloskar generators

Bhaskar India

KIRLOSKAR AUTHORIZED DEALER 

82.5 - 125 KVA

Prime Rating at rated rpm ( as per ISO8528)1
kVA
82.5
100
125
125HD

kW
66
80
100
100

Genset Model

KG1- 82.5WS
KG1- 100WS
KG1- 125WS
KG1-125WS HD

Frequency
Hz
50
50
50
50

Power factor
lagging
0.8
0.8
0.8
0.8

Voltage
V
415 3Ø
415 3Ø
415 3Ø
415 3Ø

Governing class (As per ISO 8528 Part-V)

G2
G3
G3
G3

Noise level
dBA
< 75
< 75
< 75
< 75

Fuel Consumption*
At 100 % Load
Ltrs/hr
18.8
21.9
27.4
29.6

At 75 % Load
13.8
16.9
20.2
22.4

At 50 % Load
9.9
12.2
15.3
15.3

Fuel tank capacity
Ltrs
150
230
230
230

Overall dimensions of genset (L x W x H)^
mm
3200 x
1100 x
1595
3200 x
1300 x
1795
3200 x
1300 x
1795
3650 x
1350 x
1915

Dry weight of genset with canopy (approx..)^
Kg
1710
2040
2090
2450

Wet weight of genset with canopy (approx..)^
Kg
1840
2240
2290
2650

Electrical Battery starting voltage 
Volts-DC
12
12
12
12

ENGINE
Engine Model

4R1040TA G1
4K1080TA G2
4K1080TA G2
6R1080TA G1
Rated output (Prime Continuous rating as per
)
kW
74.8
114.7
114.7
114.7
HP
102
156
156
156
No. of cylinder 
Number
4
4
4
6
Cubic capacity 2
Ltrs
4.16
4.32
4.32
6.49
Bore x Stroke
mm
105 x 120
105 x 125
105 x 125
105 x 125
Rated Speed
RPM
1500
1500
1500
1500
Aspiration
NA/TC/TA
TA
TA
TA
TA
Lube Oil change period
hrs.
500
500
500
500
Lube oil Sump Capacity
Ltrs
10
18
18
12
Coolant Capacity
Ltrs
24
21
21
28
ALTERNATOR
Insulation Class

Class H
Alternator Efficiency (at 100% load) 0.8 pf**
%
91.4
92.0
92.5
92.5
Max Voltage Dip at Full Load 0.8 pf Lag

< 20 %
< 20 %
< 20 %
< 20 %
Max Time to build up rated voltage at Rated RPM
sec
< 5 sec provided engine reach the rated speed
For intermediate ratings, kindly contact nearest KOEL office
Notes
^ Tolerances Apply
*With 0.845 Specific Gravity of diesel ( 5 % Tolerance )






5 - 30 kVA

Prime Rating at rated rpm ( as per ISO8528)1
kVA
5
7.5
10
15
20
25
30
kW
4
6
8
12
16
20
24
Genset Model

KG1-5AS
KG1-7.5AS
KG1-10AS1
KG1-15AS
KG1-20WS
KG1-25AS
KG1-30WS
Frequency
Hz
50
50
50
50
50
50
50
Power factor
lagging
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Voltage
V
230 (1Ø )
230 (1Ø ) & 415  (3Ø) 
Governing class ( As per ISO 8528 Part-V)

G2
G2
G2
G2
G2
G2
G2
Noise level
dBA
< 75
< 75
< 75
< 75
< 75
< 75
< 75

Fuel Consumption*
At 100 % Load
Ltrs/Hr
1.6
2.3
3.0
4.0
5.1
6.4
7.8
At 75 % Load
1.3
1.8
2.4
3.0
3.8
5.0
6.0
At 50 % Load
1
1.4
1.8
2.2
2.7
4.0
4.5
Fuel Tank Capacity
Ltrs
70
30
30
65
65
65
65
Overall dimensions of genset (L x W x H)^
mm
1600 x
820 x
1530
1760 x
820 x
1330
1760 x
820 x
1330
1772 x
1050 x
1410
2100 x
950 x
1220
2130 x
1050 x
1520
2390 x
950 x
1230
Dry weight of genset with canopy (approx..)^
Kg
650
750
750
950
950
1050
1200
Wet weight of genset with canopy (approx..)^
Kg
700
800
800
1000
1000
1100
1250
Electrical Battery starting voltage 
Volts-DC
12
12
12
12
12
12
12
ENGINE
Engine Model

EA10 G1
EA16 G1
EA16 G1
HA294 G1
2R1040 G1
HA394 TCI G1
3R1040T G1
Rated output (Prime Continuous rating as per ISO 8528-1)
kW
7.3
11.8
11.8
15.1
18.8
23.5
30.9
HP
10
16
16
20.5
25.5
32
42
No. of cylinder 
Number
1
2
2
2
2
3
3
Cubic capacity 2
Ltrs
0.95
1.56
1.56
1.88
2.08
2.89
3.12
Bore x Stroke
mm
102 x 116
95 x 110
95 x 110
100 x 120
105 x 120
100 x 120
105 x 120
Rated Speed
RPM
1500
1500
1500
1500
1500
1500
1500
Aspiration
NA/TC/TA
NA
NA
NA
NA
NA
TC
TC
Lube Oil change period
hrs.
500
500
500
500
500
500
500
Lube oil Sump Capacity
Ltrs
3.5
6.5
6.5
5.0
5.5
8.0
8.0
Coolant Capacity
Ltrs
NA
NA
NA
NA
9
NA
14.5
ALTERNATOR
Insulation Class

Class H
Alternator Efficiency (at 100% load) 0.8 pf**
%
78.1
78.1
78.6
86.0
88.9
88.8
89.0
Max Voltage Dip at Full Load 0.8 pf Lag
sec
 < 20 %
 < 20 %
 < 20 %
 < 20 %
 < 16 %
 < 16 %
 < 16 %
Max Time to build up rated voltage at Rated RPM
< 5 sec provided engine reach the rated speed

For intermediate ratings, kindly contact nearest KOEL office
Notes
^ Tolerances Apply
*With 0.845 Specific Gravity of diesel ( 5 % Tolerance )
** Efficiency of Alternator as per standards IS 4722 and IEC 34-1 For Site Conditions other than standard operating conditions consult KOEL for available prime power.

Prime rating and Stand‐by rating1
‘Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rating to meet their requirement. KOEL offers Prime power as standard offer. Contact KOEL for stand-by ratings.

Engine capacity does matter2
Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.
Higher engine capacity also enables Genset to respond quickly & positively to sudden load additions.

1. Canopy
·         Ease of Access and Serviceability
·         Aesthetically designed, weather and sound resistant enclosure
·         Insulation conforms to UL94-HF1 class for flammability
2. Controller
·         Microprocessor based fully configured
·         Graphical bigger LCD display
·         Best in class monitoring and diagnostic
·         Integrable with AMF


3. Engine
·         O2E Series: Low emission, high efficiency engines
·         Compact, Robust and Rugged Design
·         500 hours lube-oil change period
4. Alternator
·         Best In Class Efficiency
·         Special Windings to Reduce Harmonics
·         Vacuum Pressure Impregnation and epoxy gel coating on winding



Monitoring Features
·         Lube oil Pressure, Engine Temperature, RPM, lube oil Temperature*
·         Run Hours, No. of starts, Fuel Level, Auto / Manual Stop, Battery charge condition, AC Phase Voltage, Current, kVA, KW, KVAr, KWH, Power Factor

Optional Features
·         Modbus communication* (Features are available from 15 kVA onwards)

Diagnostic Features
KG934 Controller
·         Battery charging failure, Over speed, Under speed, Over Current, Under Voltage, Over Voltage, Over KW, Phase Sequence monitoring, Phase missing, Common Alarm, Hooter output
·         Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level alarm, Over Crank protection, Routine Maintenance indicator, Genset Test Facility, fail to start/stop
      Being in control of your Genset is certainly a winning edge!


Kirloskar Gensets Genuine Spares 
AMF Paels, AVR, , Exhaust piping, Genset shifting and complete Installation 

call - 9891501118


Complete Acoustic solution
room acoustic, Genset Canopy, sound proof partion, louvers, Audiometric booth, sound proofing of studio , music rooms and confrence rooms

Kirloskar Gensets - sale, service, rental and spares, Genset Installation & Shifting
** Efficiency of Alternator as per standards IS 4722 and IEC 34-1 For Site Conditions other than standard operating conditions consult KOEL for available prime power.

No comments: